Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Cureus ; 15(11): e48455, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38074060

RESUMO

The complex structure of the liver and its elaborate hemodynamics can cause hepatic pseudolesions on contrast-enhanced imaging, making the interpretation of diagnostic liver imaging challenging. Aberrant gastric veins are rare; most of their epidemiology data comes from small single-center studies. While current literature suggests that pseudolesions originating from aberrant gastric veins mainly present as hyperdense defects, some cases can also show up as hypodense, as shown in these cases. Differences in flow rates between the portal and aberrant veins and the timing of the scans could explain this contradiction. Identifying aberrant gastric veins on cross-sectional imaging is crucial because they could be misdiagnosed as liver lesions, granting further unnecessary workups or invasive procedures. Aberrant gastric veins can also act as pathways for the spread of gastric cancer. This manuscript presents one aberrant right gastric vein and two aberrant left gastric veins causing hepatic pseudolesions.

3.
Cureus ; 15(8): e43021, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37680421

RESUMO

Zenker's diverticulum treatment options range from endoscopic rigid or flexible procedures to surgery. There are limited studies available comparing these techniques. Frequently, the choice of treatment depends on the physician's preference or experience, as well as the institution's resources and capacity. Therefore, this study aims to define the best approach based on the highest efficacy and the lowest severe adverse events. In accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, a comprehensive search was performed. Only comparative studies were included, analyzing flexible endoscopy versus rigid endoscopy or surgery. The outcomes analyzed were clinical and technical success, severe adverse events, length of stay, and duration of the procedure. Analysis was performed using Review Manager 5.4.1 (RevMan 5.4, The Cochrane Collaboration, The Nordic Cochrane Centre, Copenhagen, Denmark). Eight retrospective cohort studies met the inclusion criteria. A total of 1281 patients were identified, 492 underwent flexible endoscopy, 453 underwent rigid endoscopy, and 336 underwent surgery. There was no difference in clinical success [risk difference (RD), 0.07 (95% CI -0.05 to 0.19%); P = 0.26], technical success [RD, 0.07 (95% CI -0.03 to 0.16); P = 0.18], severe adverse events [RD, -0.03 (95% CI -0.13 to 0.07; P = 0.052), perforation [RD, 0.07 (95% CI -0.04 to 0.19); P = 0.22] or procedure time [mean difference (MD), - 10.03 (95% CI -26.93 to 6.88); P = 0.24). There was lower length of stay with flexible endoscopy compared to the other approaches [MD, -1.98 (95% CI -3.56 to -0.40); P = 0.001]. Based on the current evidence, the three main techniques are effective for the treatment of Zenker's diverticulum. Although there was no significant difference in the safety of each technique in this meta-analysis, this result should be interpreted cautiously due to the limited data and the risk of vies between the techniques, considering that the results tend to favor flexible endoscopy, mainly explained by the newer and safer devices. Length of stay is lower with flexible endoscopy versus the other techniques, which can be beneficial considering the geriatric populations where Zenker's diverticulum mainly occurs.

5.
Radiology ; 307(5): e222855, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37367445

RESUMO

Background Various limitations have impacted research evaluating reader agreement for Liver Imaging Reporting and Data System (LI-RADS). Purpose To assess reader agreement of LI-RADS in an international multicenter multireader setting using scrollable images. Materials and Methods This retrospective study used deidentified clinical multiphase CT and MRI and reports with at least one untreated observation from six institutions and three countries; only qualifying examinations were submitted. Examination dates were October 2017 to August 2018 at the coordinating center. One untreated observation per examination was randomly selected using observation identifiers, and its clinically assigned features were extracted from the report. The corresponding LI-RADS version 2018 category was computed as a rescored clinical read. Each examination was randomly assigned to two of 43 research readers who independently scored the observation. Agreement for an ordinal modified four-category LI-RADS scale (LR-1, definitely benign; LR-2, probably benign; LR-3, intermediate probability of malignancy; LR-4, probably hepatocellular carcinoma [HCC]; LR-5, definitely HCC; LR-M, probably malignant but not HCC specific; and LR-TIV, tumor in vein) was computed using intraclass correlation coefficients (ICCs). Agreement was also computed for dichotomized malignancy (LR-4, LR-5, LR-M, and LR-TIV), LR-5, and LR-M. Agreement was compared between research-versus-research reads and research-versus-clinical reads. Results The study population consisted of 484 patients (mean age, 62 years ± 10 [SD]; 156 women; 93 CT examinations, 391 MRI examinations). ICCs for ordinal LI-RADS, dichotomized malignancy, LR-5, and LR-M were 0.68 (95% CI: 0.61, 0.73), 0.63 (95% CI: 0.55, 0.70), 0.58 (95% CI: 0.50, 0.66), and 0.46 (95% CI: 0.31, 0.61) respectively. Research-versus-research reader agreement was higher than research-versus-clinical agreement for modified four-category LI-RADS (ICC, 0.68 vs 0.62, respectively; P = .03) and for dichotomized malignancy (ICC, 0.63 vs 0.53, respectively; P = .005), but not for LR-5 (P = .14) or LR-M (P = .94). Conclusion There was moderate agreement for LI-RADS version 2018 overall. For some comparisons, research-versus-research reader agreement was higher than research-versus-clinical reader agreement, indicating differences between the clinical and research environments that warrant further study. © RSNA, 2023 Supplemental material is available for this article. See also the editorials by Johnson and Galgano and Smith in this issue.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Feminino , Pessoa de Meia-Idade , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X , Meios de Contraste , Sensibilidade e Especificidade
6.
J Clin Med ; 11(3)2022 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-35160023

RESUMO

INTRODUCTION: Heart failure (HF) and cancer are currently the leading causes of death worldwide, with an increasing incidence with age. Little is known about the treatment received and the prognosis of patients with acute HF and a prior cancer diagnosis. OBJECTIVE: to determine the clinical characteristics, palliative treatment received, and prognostic impact of patients with acute HF and a history of solid tumor. METHODS: The EPICTER study ("Epidemiological survey of advanced heart failure") is a cross-sectional, multicenter project that consecutively collected patients admitted for acute HF in 74 Spanish hospitals. Patients were classified into two groups according to whether they met criteria for acute HF with and without solid cancer, and the groups were subsequently compared. A multivariable logistic regression analysis was conducted, using the forward stepwise method. A Kaplan-Meier survival analysis was performed to evaluate the impact of solid tumor on prognosis in patients with acute HF. RESULTS: A total of 3127 patients were included, of which 394 patients (13%) had a prior diagnosis of some type of solid cancer. Patients with a history of cancer presented a greater frequency of weight loss at admission: 18% vs. 12% (p = 0.030). In the cancer group, functional impairment was noted more frequently: 43% vs. 35%, p = 0.039). Patients with a history of solid cancer more frequently presented with acute HF with preserved ejection fraction (65% vs. 58%, p = 0.048) than reduced or mildly reduced. In-hospital and 6-month follow-up mortality was 31% (110/357) in patients with solid cancer vs. 26% (637/2466), p = 0.046. CONCLUSION: Our investigation demonstrates that in-hospital mortality and mortality during 6-month follow-up in patients with acute HF were higher in those subjects with a history of concomitant solid tumor cancer diagnosis.

7.
Rev Esp Patol ; 54(3): 188-192, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34175031

RESUMO

Carcinoma of the rete testis is a rare malignant tumor which frequently occurs in middle-aged to older patients and has an aggressive biological behavior. We present the case of a 57-year-old man who presented with an ill-defined mass in the right testicle. The patient underwent a radical orchidectomy. Microscopic evaluation showed a neoplasm displaying a complex papillary-cystic architecture, infiltrating the testicular parenchyma. An in situ proliferation of neoplastic cells, with nuclear stratification and scanty cytoplasm was seen at the periphery, within the channels of the rete testis. The tumor infiltrated the tunica albuginea focally without disrupting it completely. Immunohistochemistry was positive for AE1/AE3, CK7, CK34ßE12, D2-40, and PAX8. Imaging studies presented no evidence of metastatic disease. These findings are those of a primary rete testis carcinoma. The transition between benign and neoplastic rete testis epithelium served as a helpful diagnostic clue. Metastatic carcinomas from other sites were considered in the differential diagnosis.


Assuntos
Carcinoma/patologia , Rede do Testículo/patologia , Neoplasias Testiculares/patologia , Carcinoma/química , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Proteínas de Neoplasias/análise , Rede do Testículo/química , Neoplasias Testiculares/química
8.
Abdom Radiol (NY) ; 46(1): 205-215, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32488557

RESUMO

PURPOSE: To perform an international survey on current practices in imaging-based surveillance, diagnosis, staging, and assessment of treatment response for HCC. MATERIALS AND METHODS: Three themes were covered in this international survey: demographics of respondents and liver imaging expertise; imaging practices for screening, surveillance, diagnosis, staging, and assessment of treatment response for HCC; and diagnostic imaging systems used. Descriptive summaries were created. RESULTS: Of 151 respondents, 22.5% were from Asia, 6.0% from Europe, 19.9% from North America, 26.5% from South America, and 25.2% from Australasia; 57.0% respondents worked in academic and 34.4% in private or mixed settings. Non-contrast ultrasound was most commonly used for screening and surveillance of HCC (90.7%), and multiphase computed tomography was used for diagnosis (96.0%). Extracellular contrast agents (69.5%) were the most commonly used MRI contrast agents and Lumason/SonoVue (31.1%) is the most commonly used contrast-enhanced ultrasound contrast agent. A majority (94.0%) of respondents use ancillary imaging features for assessment of liver lesions in at-risk patients. Usage of diagnostic imaging systems for HCC varied by region. RECIST or mRECIST criteria were most commonly used for assessing HCC treatment response (48.3%). Most respondents agreed that a standardized classification for the diagnosis of HCC is needed (68.9%) and that an atlas and lexicon would help improve inter-reader agreement (71.5%). CONCLUSION: Practices and recommendations for imaging of HCC vary between geographical regions. Future efforts to develop a unified system should address regional differences and potential barriers for adoption of a standardized diagnostic system for HCC.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Europa (Continente) , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , América do Norte , Inquéritos e Questionários , Ultrassonografia
9.
NOVA publ. cient ; 18(33): 101-112, ene.-jun. 2020. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1149451

RESUMO

Resumen Objetivo. Determinar características bacteriológicas, físicas y pH del agua para consumo humano que abastece al municipio de Une, Cundinamarca-Colombia. Métodos. Se tomaron 13 muestras de agua: 10 de la zona rural y 3 de la zona urbana. Del total de muestras tomadas en la zona rural, 7 no tenían ningún tratamiento, mientras que 3 tenían algún tipo de tratamiento. Las 3 muestras tomadas en la cabecera municipal, todas tenían tratamiento. Se utilizó la técnica de filtración por membrana para los análisis bacteriológicos, y los métodos nefelométrico, turbidimétrico y potenciométrico, para los análisis físicos y el pH. Resultados. Se obtuvo como resultado pH inferior a 6; 12 puntos superan el valor máximo de turbiedad y 5 puntos para la determinación de color. Se observó la presencia de Coliformes totales, E. coli y Enterococcus en las muestras analizadas, en cantidad que sobrepasa lo establecido en la normativa colombiana.


Abstract Objective. To determine bacteriological and physical characteristics and pH of water for human consumption that supplies the municipality of Une, Cundinamarca-Colombia. Methods. Thirteen water samples were taken: 10 from the rural area and 3 from the urban area. Of the total number of samples taken in the rural area, 7 had no treatment at all, while 3 had some type of treatment. The 3 samples taken in the municipal capital, all had treatment. The membrane filtration technique was used for bacteriological analysis and the nephelometric, turbidimetric and potentiometric methods for physical analysis and pH. Results. The result was pH lower than 6; 12 points exceed the maximum value turbidity and 5 points for the determination of color. The presence of total Coliforms, E. coli and Enterococcus was observed in the analyzed samples, in an amount that surpasses the established in the Colombian regulations.


Assuntos
Água , Água Potável , Amostras de Água , Técnicas Bacteriológicas , Enterococcus
11.
J Surg Case Rep ; 2018(9): rjy246, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30254733

RESUMO

Wilkie's syndrome is a rare cause of duodenal obstruction that can easily be missed at clinical practice. It is characterized by nausea, abdominal pain and vomit. It usually affects young adults, and it's caused by a low aortomesenteric angle resulting in vascular compression of the duodenum. Symptoms could resemble many of the symptoms presented in a patient with a suspected eating disorder. The non-specificity of the clinical signs and symptoms can confuse, delay the diagnosis and expose the patient to potentially hazardous therapies. We report a case of a 20-year-old patient who presented to the emergency room with a history of intermittent vomiting and abdominal pain. He had been previously misdiagnosed with an eating disorder and received physiological therapy. Nonetheless, his pain persisted. After further evaluation with the use of imaging techniques, a low aortomesenteric angle was discovered. He underwent surgery and completely recovered. On follow up controls patient is well and he no longer had episodes of vomiting.

12.
Int. braz. j. urol ; 44(4): 688-696, July-Aug. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-954075

RESUMO

ABSTRACT Objectives: To evaluate the diagnostic performance of preoperative multiparametric magnetic resonance imaging (mp-MRI) as a predictor of extracapsular extension (ECE) and unfavorable Gleason score (GS) in patients with intermediate and high-risk prostate cancer (PCa). Materials and Methods: Patients with clinically localized PCa who underwent radical prostatectomy (RP) and had preoperative mp-MRI between May-2011 and December-2013. Mp-MRI was evaluated according to the European Society of Urogenital Radiology MRI prostate guidelines by two different readers. Histopathological RP results were the standard reference. Results: 79 patients were included; mean age was 61 and median preoperative prostate-specific antigen (PSA) 7.0. On MRI, 28% patients had ECE evidenced in the mp-MRI, 5% seminal vesicle invasion (SVI) and 4% lymph node involvement (LNI). At RP, 39.2% had ECE, 26.6% SVI and 12.8% LNI. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of mp-MRI for ECE were 54.9%, 90.9%, 76%, 81% and 74.1% respectively; for SVI values were 19.1%, 100%, 77.3%, 100% and 76.1% respectively and for LNI 20%, 98.4%, 86.7%, 66.7% and 88.7%. Conclusions: Major surgical decisions are made with digital rectal exam (DRE) and ultrasound studies before the use of Mp-MRI. This imaging study contributes to rule out gross extraprostatic extension (ECE, SVI, LNI) without competing with pathological studies. The specificity and NPV are reasonable to decide surgical approach. A highly experienced radiology team is needed to provide accurate estimations of tumor extension and aggressiveness.


Assuntos
Humanos , Masculino , Adulto , Idoso , Neoplasias da Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Glândulas Seminais/patologia , Glândulas Seminais/diagnóstico por imagem , Biópsia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Antígeno Prostático Específico/sangue , Medição de Risco/métodos , Gradação de Tumores , Linfonodos/patologia , Linfonodos/diagnóstico por imagem , Pessoa de Meia-Idade , Invasividade Neoplásica/patologia , Estadiamento de Neoplasias
13.
Biosens Bioelectron ; 117: 522-529, 2018 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-29982123

RESUMO

Multiplexed electrochemical biosensors are intriguing due to their capability to permit high-throughput and low-cost assays. While commercial single-chip potentiostats are one promising approach for rapidly prototyping portable and low-cost electrochemical biosensors, it is still challenging to utilize them to achieve parallel multiplexing due to the limited resources integrated onto the chips. In this paper, we provide a methodology for incorporating multiplexing into commercial single-chip potentiostats by using a sequential architecture. In the sequential architecture, the multiplexed biosensors are interfaced to the single-chip potentiostat via single-pole single-throw switches, and the measurements alternate across the sensors. We build analytical and finite element models to investigate the behavior of the sensors, particularly when they are disconnected from the potentiostat, and find that we can take advantage of the dynamics of the sensors to achieve improved sensitivity over conventional chronoamperometry. We also investigate and compare different strategies to interface the multiplexed sensors to the single-chip potentiostat. Using the proposed multiplexing architecture, we demonstrate the implementation of 16-fold multiplexed amperometry, which is validated using ferricyanide measurement. Finally, the sequential multiplexing methodology is applied to a multiplexed bead-based electronic enzyme-linked immunosorbent assays of human interleukin-6.


Assuntos
Técnicas Biossensoriais/métodos , Eletroquímica , Interleucina-6/análise , Técnicas Biossensoriais/instrumentação , Humanos
14.
Int Braz J Urol ; 44(4): 688-696, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29570254

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of preoperative multiparametric magnetic resonance imaging (mp-MRI) as a predictor of extracapsular extension (ECE) and unfavorable Gleason score (GS) in patients with intermediate and high-risk prostate cancer (PCa). MATERIALS AND METHODS: Patients with clinically localized PCa who underwent radical prostatectomy (RP) and had preoperative mp-MRI between May-2011 and December-2013. Mp-MRI was evaluated according to the European Society of Urogenital Radiology MRI prostate guidelines by two different readers. Histopathological RP results were the standard reference. RESULTS: 79 patients were included; mean age was 61 and median preoperative prostate-specific antigen (PSA) 7.0. On MRI, 28% patients had ECE evidenced in the mp-MRI, 5% seminal vesicle invasion (SVI) and 4% lymph node involvement (LNI). At RP, 39.2% had ECE, 26.6% SVI and 12.8% LNI. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of mp-MRI for ECE were 54.9%, 90.9%, 76%, 81% and 74.1% respectively; for SVI values were 19.1%, 100%, 77.3%, 100% and 76.1% respectively and for LNI 20%, 98.4%, 86.7%, 66.7% and 88.7%. CONCLUSIONS: Major surgical decisions are made with digital rectal exam (DRE) and ultrasound studies before the use of Mp-MRI. This imaging study contributes to rule out gross extraprostatic extension (ECE, SVI, LNI) without competing with pathological studies. The specificity and NPV are reasonable to decide surgical approach. A highly experienced radiology team is needed to provide accurate estimations of tumor extension and aggressiveness.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Adulto , Idoso , Biópsia , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Invasividade Neoplásica/patologia , Estadiamento de Neoplasias , Antígeno Prostático Específico/sangue , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Reprodutibilidade dos Testes , Medição de Risco/métodos , Glândulas Seminais/diagnóstico por imagem , Glândulas Seminais/patologia , Sensibilidade e Especificidade
15.
AJR Am J Roentgenol ; 205(6): 1188-93, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26587924

RESUMO

OBJECTIVE: The objective of our study was to systematically summarize the published evidence of demographic, clinical, diagnostic imaging, and therapeutic characteristics of patients with multilocular cystic nephroma (MLCN). CONCLUSION: Cross-sectional imaging evaluation is important for suggesting the diagnosis of MLCN but has several limitations. The number of radical nephrectomies reported for MLCN encourages discussion concerning the utility of percutaneous presurgical biopsy and frozen-section intraoperative biopsy as a more conservative diagnostic approach.


Assuntos
Doenças Renais Císticas/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Tumor de Wilms/diagnóstico por imagem , Biópsia , Meios de Contraste , Humanos , Doenças Renais Císticas/patologia , Doenças Renais Císticas/cirurgia , Neoplasias Renais/patologia , Neoplasias Renais/cirurgia , Nefrectomia , Tumor de Wilms/patologia , Tumor de Wilms/cirurgia
16.
Radiographics ; 35(1): 87-104, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25590390

RESUMO

Orthotopic liver transplantation is becoming an increasingly routine procedure for a variety of benign and malignant diseases of the liver and biliary system. Continued improvements in surgical techniques and post-transplantation immunosuppression regimens have resulted in better graft and patient survival. A number of potentially treatable nonvascular complications of liver transplantation are visible at imaging, and accurate diagnosis of these complications allows patients to benefit from potential treatment options. Biliary complications include stricture (anastomotic and nonanastomotic), leak, biloma formation, and development of intraductal stones. Pathologic conditions, including hepatitis C infection, hepatocellular carcinoma, hepatic steatosis, and primary sclerosing cholangitis, may recur after liver transplantation. Transplant patients are at increased risk for developing de novo malignancy, including post-transplantation lymphoproliferative disorder, which results from immunosuppression. Patients are also at increased risk for systemic infection from immunosuppression, and patients with hepatic artery and biliary complications are at increased risk for liver abscess. Transplant recipients are typically followed with serial liver function testing; abnormal serum liver function test results may be the first indication that there is a problem with the transplanted liver. Ultrasonography is typically the first imaging test performed to try to identify the cause of abnormal liver function test results. Computed tomography, magnetic resonance imaging, angiography, and/or cholangiography may be necessary for further evaluation. Accurately diagnosing nonvascular complications of liver transplantation that are visible at imaging is critically important for patients to benefit from appropriate treatment.


Assuntos
Diagnóstico por Imagem , Transplante de Fígado , Complicações Pós-Operatórias/diagnóstico , Meios de Contraste , Humanos , Testes de Função Hepática , Recidiva
17.
Radiographics ; 34(7): 2025-38, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25384299

RESUMO

Posttransplantation lymphoproliferative disease (PTLD) is the second most common tumor in adult transplant recipients. Most cases of PTLD are attributed to Epstein-Barr virus. Decreased levels of immunosurveillance against this tumor virus as a result of immunosuppressive regimens are thought to account for most cases of PTLD. Histologically, PTLD ranges from relatively benign lymphoid hyperplasia to poorly differentiated lymphoma, and tissue sampling is required to establish the subtype. The frequency of PTLD varies depending on the type of allograft and immunosuppressive regimen. PTLD has a bimodal manifestation, with most cases occurring within the first year after transplantation and a second peak occurring 4-5 years after transplantation. Patients are often asymptomatic or present with nonspecific symptoms, and a mass visible at imaging may be the first clue to the diagnosis. Imaging plays an important role in identifying the presence of disease, guiding tissue sampling, and evaluating response to treatment. The appearance of PTLD at imaging can vary. It may be nodal or extranodal. Extranodal disease may involve the gastrointestinal tract, solid organs, or central nervous system. Solid organ lesions may be solitary or multiple, infiltrate beyond the organ margins, and obstruct organ outflow. Suggestive imaging findings should prompt tissue sampling, because knowledge of the PTLD subtype is imperative for appropriate treatment. Treatment options include reducing immunosuppression, chemotherapy, radiation therapy, and surgical resection of isolated lesions.


Assuntos
Diagnóstico por Imagem , Transtornos Linfoproliferativos/diagnóstico , Transplante de Órgãos/efeitos adversos , Humanos , Hospedeiro Imunocomprometido , Terapia de Imunossupressão/efeitos adversos , Imunossupressores/efeitos adversos , Transtornos Linfoproliferativos/epidemiologia , Transtornos Linfoproliferativos/etiologia , Transtornos Linfoproliferativos/fisiopatologia , Fatores de Risco
18.
AJR Am J Roentgenol ; 202(6): 1272-80, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24848825

RESUMO

OBJECTIVE: The purpose of this study was to compare the diagnostic accuracy achieved with and without the calibration method established by the DICOM standard in both medical-grade gray-scale displays and consumer-grade color displays. MATERIALS AND METHODS: This study involved 76 cases, six radiologists, three displays, and two display calibrations for a total of 2736 observations in a multireader-multicase factorial design. The evaluated conditions were interstitial opacities, pneumothorax, and nodules. CT was adopted as the reference standard. One medical-grade gray-scale display and two consumer-grade color displays were evaluated. Analyses of ROC curves, diagnostic accuracy (measured as AUC), accuracy of condition classification, and false-positive and false-negative rate comparisons were performed. The degree of agreement between readers was also evaluated. RESULTS: No significant differences in image quality perception by the readers in the presence or absence of calibration were observed. Similar forms of the ROC curves were observed. No significant differences were detected in the observed variables (diagnostic accuracy, accuracy of condition classification, false-positive rates, false-negative rates, and image-quality perception). Strong agreement between readers was also determined for each display with and without calibration. CONCLUSION: For the chest conditions and selected observers included in this study, no significant differences were observed between the three evaluated displays with respect to accuracy performance with and without calibration.


Assuntos
Terminais de Computador/estatística & dados numéricos , Terminais de Computador/normas , Apresentação de Dados/normas , Radiografia Torácica/instrumentação , Radiografia Torácica/normas , Software/normas , Colômbia , Cor , Desenho de Equipamento , Segurança de Equipamentos , Humanos , Variações Dependentes do Observador , Guias de Prática Clínica como Assunto , Radiografia Torácica/estatística & dados numéricos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software/estatística & dados numéricos
19.
Telemed J E Health ; 20(4): 304-11, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24506568

RESUMO

INTRODUCTION: In teleradiology services and in hospitals, the extensive use of visualization displays requires affordable devices. The purpose of this study was to compare three differently priced displays (a medical-grade grayscale display and two consumer-grade color displays) for image visualization of digitized chest X-rays. MATERIALS AND METHODS: The evaluated conditions were interstitial opacities, pneumothorax, and nodules using computed tomography as the gold standard. The comparison was accomplished in terms of receiver operating characteristic (ROC) curves, the diagnostic power measured as the area under ROC curves, accuracy in conditions classification, and main factors affecting accuracy, in a factorial study with 76 cases and six radiologists. RESULTS: The ROC curves for all of the displays and pathologies had similar shapes and no differences in diagnostic power. The proportion of cases correctly classified for each display was greater than 71.9%. The correctness proportions of the three displays were different (p<0.05) only for interstitial opacities. The evaluation of the main factors affecting these proportions revealed that the display factor was not significant for either nodule size or pneumothorax size (p>0.05). CONCLUSIONS: Although the image quality variables showed differences in the radiologists' perceptions of the image quality of the three displays, significant differences in the accuracy did not occur. The main effect on the variability of the proportions of correctly classified cases did not come from the display factor. This study confirms previous findings that medical-grade displays could be replaced by consumer-grade color displays with the same image quality.


Assuntos
Apresentação de Dados/economia , Radiografia Torácica/economia , Radiografia Torácica/instrumentação , Telerradiologia/economia , Telerradiologia/instrumentação , Tomografia Computadorizada por Raios X/economia , Tomografia Computadorizada por Raios X/instrumentação , Humanos , Intensificação de Imagem Radiográfica/economia , Intensificação de Imagem Radiográfica/instrumentação , Software , Ecrans Intensificadores para Raios X/economia
20.
J Digit Imaging ; 27(2): 280-6, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24149967

RESUMO

This study focused on the effects of pneumothorax size quantification in digital radiology environments when a quantification method is selected according to the radiologist's criteria. The objective of this study was to assess the effects of factors, including the radiologist (with different experience), displays (medical-grade and consumer-grade displays), or display calibration, on the Rhea, Collins, and Light quantification methods. This study used a factorial design with 76 cases, including 16 pneumothorax cases observed by six radiologists on three displays with and without the DICOM standard calibration. The gold standard was established by two radiologists by using computed tomography. Analysis of variance (ANOVA) was performed on the pneumothorax sizes. For the three quantifications methods, none of the evaluated factors were significant. We conclude that radiologists, displays, and calibration do not significantly affect the quantification of pneumothorax size in different digital radiology environments.


Assuntos
Pneumotórax/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Calibragem , Cor , Apresentação de Dados , Humanos , Software , Telerradiologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...